Eltima Serial Port Monitor 6 Crackers
- Read: Displays a number of bytes read from serial port. Written: Displays a number of bytes written to serial port. Serial port control information: This is a string of 4 or 5 items, separated by dash: nBaudRate: Defines serial port baudrate. Possible values are: 110, 300, 600, 1200, 2400, 4800, 9600, 14400, 19200, 38400, 56000, 57600, 115200.
- Serial Port Monitor by Eltima. This high-quality application delivers a full-featured and comprehensive tool for monitoring COM port traffic. Serial Port Monitor is a solution for discovering and breaking down problems that may occur during the test and optimization COM port devices' performance and more.
Send dialog is available in Professional and Company Editions only.
The Eltima serial port monitor free download allows you to monitor the use of the serial port supported by your system. Serial Port Monitor is a professional and powerful system utility for RS232/422/485 ports monitoring. COM monitor displays, logs and analyzes. Get Eltima Serial Port Monitor 6.0.235 for Free!
Send dialog allows you to open/close a serial port, change serial port parameters on-the-fly and send the data in different numeral systems (binary, octal, decimal, hexadecimal) as well as strings. Chromecast screenshare for mac. Similo: history for mac. Besides, you can select any file which contains binary data and send it in blocks.
Send dialog is usually docked at the bottom of the main window. However, if it is not visible there, you might wish to display it using “View -> Toolbars -> Send dialog ” option of the main menu.
Send dialog offers the following features:
- Port : Select existing serial port to open.
- Baudrate : Specify rate at which bits are transmitted (bits per second). The baud rate is the rate at which information is transferred in a communication channel. In the serial port context, “9600 baud” means that the serial port is capable of transferring a maximum of 9600 bits per second. To be able to communicate at the maximum speed, both local and remote ends must be configured to the same baud rate and pass handshake stage before you can successfully read or write data. Send dialog supports all standard baud rates (100, 300, 600, 1200, 2400, 4800, 9600, 14400, 19200, 38400, 57600, 115200, 128000, and 256000 bits per second).
- Data bits : Specify number of data bits to transmit. Usually, the transferred bits include the start bit, the data bits, the parity bit (if used), and the stop bits. However, only the data bits carry useful information.You can configure DataBits to be 5, 6, 7, or 8. Data is transmitted as a series of five, six, seven, or eight bits with the least significant bit sent first (little-endian). At least seven data bits are required to transmit ASCII characters. Eight bits are required to transmit binary data. Five and six bit data formats are used for specialized communication equipment.
- Parity : Specify the parity checking type. Parity can be one of the following: none, odd, even, mark, or space. If Parity is none, parity checking is not performed and the parity bit is not transmitted. If Parity is odd, the number of mark bits (1s) in the data is counted, and the parity bit is asserted or unasserted to obtain an odd number of mark bits. If Parity is even, the number of mark bits in the data is counted, and the parity bit is asserted or unasserted to obtain an even number of mark bits. If Parity is mark, the parity bit is asserted. If Parity is space, the parity bit is unasserted.
- Stop bits : Specify number of bits used to indicate end of a byte. Stop bits could be 1, 1.5, or 2, however almost all contemporary devices are configured to 1 Stop bit. Please, note that both ends of serial port must be configured to transmit the same number of stop bits to work properly.
- Flow control : Specify the Flow control type. Flow control is usually used to ensure that the receiving serial port device can handle all of the incoming data sent to it. Send dialog provides the following values you can assign to Flow control: Xon/Xoff (commonly used for asynchronous communication), Hardware and None.
- Send combo-box : Here you may type in and send any type of data in blocks by selecting corresponding radio button below. Additionally, you may select from the list of previously sent data blocks.
- Send file : You can select any file which contains binary data and send it in blocks. By default the file type is “txt”, but you can select another one.
- Start loop combo-box : It is a convenient function which enables you to loop commands execution automatically, sending commands at variable time.
- String, Hex, Dec, Oct and Bin : This block of radio-buttons allows you to specify the format of the data to be transmitted. You may select from text strings (String), hexadecimal (Hex), decimal (Dec), octal (Oct) or binary (Bin) data formats. To be able to send hexadecimal characters along with strings you should enable corresponding option in Preferences dialog.Since Serial Port Monitor sends data in packets you are limited to a single byte value which is 255. For instance you cannot send value higher than FF in hexadecimal format, 377 in octal, 255 in decimal and 11111111 in binary. This is similar to the way this issue is handled in Scientific calculator when you are operating in byte’s mode.
Eltima Software Serial Port Monitor Pro 6.0.235
Eltima Software Serial Port Monitor Pro 6.0.235 17 Mb
Serial Port Monitor is a professional and powerful system utility for RS232/422/485 ports monitoring. COM monitor displays, logs and analyzes all serial port activity in a system. This is an ideal way to track down problems that may occur during application or driver development, testing and optimization of serial devices, etc.
Serial Monitor also offers advanced filtering and search, professional built-in terminal and data exporting options, user-friendly and flexible interface among its key advantages. It is a completely software solution, you don't need any additional hardware to use it.
Key Features:
- Monitoring serial ports which are already in use
- Sending/receiving data to/from any COM port (Advanced Send Dialog)
- The possibility to change COM port parameters from Advanced Send Dialog
- Any serial port software/hardware can be analyzed
- Monitor any number of serial ports at once
- Supports all COM-port types
- Intercepts all data read from/written to COM port
- Built-in search
- 4 types of customizable monitoring visualizers for viewing and logging data
- Incoming and outgoing data streams logging
Analyze serial port activity
Serial Port Monitor can connect to a COM port, which is even already opened by any application, and can start monitoring it right away. All the data that goes through the monitored COM port will show up in our monitoring tool. Everything is captured in real-time, so you can track down problems immediately.
Moreover, you can redirect all the monitoring data to the specified file or you can copy all recorded data to clipboard. Serial Port Monitor gives you the ability to intercept and record all serial input/output control codes (IOCTLs), tracking their full details and parameters. You can save any monitoring session and load it next time whenever you need it.
Monitor several ports within one session
Serial Port Monitor has a unique functionality of monitoring several COM-ports simultaneously. Now you can collect data on how apps interact with two or more ports and a few devices concurrently within one session. Data received and sent during monitoring will be presented (recorded) in a single log on a first-in first-out basis; this makes it more convenient for analysis.
Read captured data in different ways
You can view data in all 4 monitoring views at the same time: table, line, dump or terminal mode, each providing a different way to represent recorded serial data. COM Monitor lets you choose monitoring filters, thus saving your time and letting you track down only those events you are interested in.
Emulate data sending to serial device
Eltima Serial Port Monitor 6 Crackers Recipe
You can send data in various formats (string, binary, octal, decimal, hexadecimal, mixed) to monitored serial port as if it was sent on behalf of monitored application using terminal mode feature of Serial Monitor. Thus you can follow the reaction of the monitored serial device to some special commands and data.What's New in Version 6.0.235:
- Fixed: visualizers selection wouldn’t apply when starting a new session via command line
- Fixed: issue when options set via menu (View - Windows) applied to the wrong view
- Fixed: Send dialog options in Preferences were not applied after saving them
- Fixed: some cases when new events were not captured after monitoring restart
- Fixed: Read/Write data filter in Preferences failed to apply to Terminal view